I have a year old worchester / bosch boiler and the pressure has gone below 1. How do i re fill it ?



Answers:
There should be a filling loop with a short hose. Connect the hose slowly open the valve, and it will fill, shut off the valve when it gets to the correct pressure.
There has to be a filling loop in every system..try looking under the system or under the sink or near other place where is a water supply.
Mine has a tap built into the water pipe, open it up and watch the guage, turn it off when the correct pressure is reached
There should be a little brass tap on a pipe coming off the boiler, twist it and you will hear a rushing noise and the pressure will go up.
Nimbus shoudln't have a tap built into the system.tut.tut

There shoudl be a link between the CH system and the cold supply. This is often a flexi coupling hose between 2 service valves as its not allowed to be a permanent connection ( to stop CH water potentially going back into the cold water system). Its often near the boiler. Connect them up and crack open the service valves, the pressure will rise . When you done close the walves and disconnect the hose.
your boiler should off had a filling key if its a cdi range
most new worcester boilers have integral filling loop
you turn key and little grey knob untill correct pressure

or ring worcester technical on 08705 266241

The answers post by the user, for information only, UKQnA.com does not guarantee the right.

  • Dwarf Apache Chilli question?
  • Are wooden shutters a good way to insulate from draughts?
  • Help pen mark !?
  • Fridge Freezer?
  • how would you servive with no electric?
  • How can I separate four baby plants from a Yucca mother plant and when is the best time to do it?
  • How much doe sit cost for lamintae flooring?
  • How do I get rid of orange stains on the toilet brush. I live in a very hard water area?